● Standard GB/T2614-1998
● Applicable conditions:
oxidation and neutral atmosphere
Temperature range: -200-1200 ℃
● Temperature the upper limit
Wire dia mm |
Long-term use temperature limit ℃ |
Short-term temperature limit ℃ |
0.3 |
700 |
800 |
0.5 |
800 |
900 |
0.8 1.0 |
900 |
1000 |
1.2 1.6 |
1000 |
1100 |
2.0 2.5 |
1100 |
1200 |
3.2 |
1200 |
1300 |
● Uneven thermo-emf
Wire dia mm |
Temperature of measuring side ℃ |
Uneven emf MV |
||
Ⅰ |
Ⅱ |
Ⅲ |
||
0.3 0.5 |
-196 |
|
|
30 |
0.3 |
700 |
35 |
70 |
|
0.5 0.8 1.0 |
800 |
40 |
80 |
|
1.2 1.6 2.0 |
1000 |
50 |
100 |
|
● Thermo-emf and tolerance
Wire dia |
Grade |
Thermocouple thermo-emf |
NiCr - Pt thermocouple thermo-emf |
|||||||||||
0.3 0.5 |
temp. point |
-79℃ |
-196℃ |
-79℃ |
-196℃ |
|||||||||
Ⅲ |
-2887±82 |
-5289±47 |
-1828±54 |
-3395±30 |
||||||||||
0.3 |
temp. point |
400℃ |
600℃ |
700℃ |
400℃ |
600℃ |
700℃ |
|||||||
Ⅰ |
16397±68 |
24905±102 |
29129±117 |
12775±46 |
19604±72 |
22922±77 |
||||||||
Ⅱ |
16397±127 |
24905±191 |
29129±220 |
12775±87 |
19604±121 |
22922±140 |
||||||||
0.5 0.8 1.0 |
temp. point |
400℃ |
600℃ |
800℃ |
400℃ |
600℃ |
800℃ |
|||||||
Ⅰ |
16397±68 |
24905±102 |
33275±131 |
12775±46 |
19604±72 |
26155±91 |
||||||||
Ⅱ |
16397±127 |
24905±191 |
33275±246 |
12775±87 |
19604±121 |
26155±140 |
||||||||
1.2 1.6 2.0 2.5 |
temp. point |
400℃ |
600℃ |
800℃ |
1000℃ |
400℃ |
600℃ |
800℃ |
1000℃ |
|||||
Ⅰ |
16397±68 |
24905±102 |
33275±131 |
45119±156 |
12775±46 |
19604±72 |
26155±91 |
32419±106 |
||||||
Ⅱ |
16397±127 |
24905±191 |
33275±246 |
45119±292 |
12775±87 |
19604±121 |
26155±140 |
32419±192 |
||||||
3.2 |
temp. point |
400℃ |
600℃ |
800℃ |
1000℃ |
400℃ |
600℃ |
800℃ |
1000℃ |
|||||
Ⅰ |
16397±68 |
24905±102 |
33275±131 |
45119±156 |
12775±46 |
19604±72 |
26155±91 |
32419±106 |
||||||
Ⅱ |
16397±127 |
24905±191 |
33275±246 |
45119±292 |
12775±87 |
19604±121 |
26155±140 |
32419±192 |
||||||