Location: Home > Products > Temperature Measurement
Industrial thermocouple wire
NiCr-CuNi (constantan) thermocouple wire

● Standard GB/T4993-1998

● Applicable conditions:

oxidation and weak reducing atmosphere
Temperature Range: -200 ~ 1000℃

● Temperature the upper limit

Wire dia mm

Long-term temperature the upper limit ℃

Short-term temperature the upper limit ℃

0.3  0.5

350

450

0.8  1.0  1.2

450

550

1.6  2.0

550

650

2.5

650

750

3.2

750

900

● Uneven Thermo-emf

Wire dia mm

temperature of measuring side ℃

Uneven thermo-emf μV

NiCr

CuCr

NiCr

CuCr

NiCr

CuCr

0.3  0.5

-196

 

 

 

 

20

30

0.3  0.5  0.8
1.0   1.2

400

40

50

70

90

 

 

1.6  2.0  2.5

600

55

75

100

140

 

 

3.2

700

60

85

115

165

 

 

● Thermo-emf and tolerance

Wire dia
mm

Grade

Thermocouple thermo-emf
tolerance at temperature measurement points μV

NiCr- Pt thermocouple thermo-emf
tolerance at temperature measurement pointsμV

0.3  0.5

temp. point

-79℃

-196℃

-79℃

-196℃

-4254±121

-8722±77

-1828±50

-3395±30

0.3  0.5

temp. point

100℃

200℃

250℃

100℃

200℃

250℃

6319±101

13421±111

 

2814±45

5970±49

 

6319±169

13421±185

 

2814±75

5970±82

 

0.8  1.0

1.2

temp. point

100℃

300℃

400℃

100℃

300℃

400℃

6319±101

21036±117

28946±128

2814±45

9323±51

12764±55

6319±169

21036±195

28946±240

2814±75

9323±85

12764±104

1.6

2.0  2.5

temp. point

100℃

300℃

400℃

600℃

100℃

300℃

400℃

600℃

6139±101

21036±117

28946±128

45093±194

2814±45

9323±51

12764±55

19618±81

6139±169

21036±195

28946±240

45093±363

2814±75

9323±85

12764±104

19618±152

3.2

temp. point

 

400℃

600℃

700℃

 

400℃

600℃

700℃

 

28946±128

45093±194

53112±223

 

12764±55

19618±81

22951±92

 

28946±240

45093±363

53112±418

 

12764±104

19618±152

2295±173