● Standard GB/T 18034-2000
● Classification and grade:
Carbon-identification (D) and temperature (C) categories. Each category according to thermal properties, tolerance and even emf, is divided into S and R type withⅠ,Ⅱgrade, B type withⅠ, Ⅱ, Ⅲ grade.
● Size tolerance and single wire weight
Dia mm |
Tolerance mm |
Out-of-roundness |
Single wire weight ≤g |
0.100 |
±0.004 |
0.004 |
25 |
0.080 |
±0.003 |
0.003 |
20 |
0.070 |
±0.002 |
0.002 |
15 |
Note: If the user need, to allow the supply of single wire weight less than standard. |
|||
● Uneven thermo-emf
Each axis of wire, the reference side temperature at 0℃, measurement end temperature of palladium point (1554.8 ℃).
Wire material |
uneven thermo-emf μV ≤ |
||
carbon-identification wire |
Ⅰ |
Ⅱ |
|
Pt |
2 |
3 |
5 |
PtRh6 |
9 |
10 |
20 |
PtRh 10 |
7 |
8 |
14 |
PtRh 13 |
7 |
8 |
16 |
PtRh 30 |
7 |
8 |
16 |
● Thermo-emf and tolerance
PtRh10-Pt, PtRh13-Pt and PtRh30-PtRh6 thermocouple wire, when the reference side temperature ℃, gold point and palladium-point value of thermal emf and tolerance.
Type |
Measurement end temperature℃ |
Thermal emf standard valueμV |
Classification |
Tolerance |
Temperature ℃ |
||||
Ⅰ |
Ⅱ |
Ⅲ |
Ⅰ |
Ⅱ |
Ⅲ |
||||
S |
1064.18 |
10 334 |
D |
12 |
- |
- |
±1 |
- |
- |
C |
24 |
31 |
- |
±2 |
±2.6 |
― |
|||
1554.8 |
16 239 |
D |
12 |
- |
- |
±1 |
- |
- |
|
C |
24 |
36 |
- |
±2 |
±3 |
- |
|||
R |
1064.18 |
11 364 |
D |
13 |
- |
- |
±1 |
- |
- |
C |
27 |
36 |
- |
±2 |
±2.6 |
- |
|||
1554.8 |
18 219 |
D |
14 |
- |
- |
±1 |
- |
- |
|
C |
28 |
42 |
- |
±2 |
±3 |
- |
|||
B |
1064.18 |
5 434 |
D |
10 |
- |
- |
±1 |
- |
- |
C |
20 |
29 |
38 |
±2 |
±3 |
±4 |
|||
1554.8 |
10 735 |
D |
18 |
- |
- |
±1.5 |
- |
- |
|
C |
24 |
36 |
48 |
±2 |
±3 |
±4 |
|||
Note: if requested, to allow the supply of ± 0.5 ℃ high-precision wire |
|||||||||