Location: Home > Products > Temperature Measurement
Industrial thermocouple wire
Precious metals S, R, B type fast thermocouple wire

● Standard GB/T 18034-2000

● Classification and grade:
Carbon-identification (D) and temperature (C) categories. Each category according to thermal properties, tolerance and even emf, is divided into S and R type withⅠ,Ⅱgrade, B type withⅠ, Ⅱ, Ⅲ grade.

● Size tolerance and single wire weight

Dia  mm

Tolerance   mm

Out-of-roundness
≤mm

Single wire weight  ≤g

0.100

±0.004

0.004

25

0.080

±0.003

0.003

20

0.070

±0.002

0.002

15

Note: If the user need, to allow the supply of single wire weight less than standard.


● Uneven thermo-emf
Each axis of wire, the reference side temperature at 0℃, measurement end temperature of palladium point (1554.8 ℃).

Wire material

uneven thermo-emf    μV    ≤

carbon-identification wire

Ⅰ   

Ⅱ    

Pt

2

3

5

PtRh6

9

10

20

PtRh 10

7

8

14

PtRh 13

7

8

16

PtRh 30

7

8

16

● Thermo-emf and tolerance
PtRh10-Pt, PtRh13-Pt and PtRh30-PtRh6 thermocouple wire, when the reference side temperature ℃, gold point and palladium-point value of thermal emf and tolerance.

Type 

Measurement end temperature℃

Thermal emf standard valueμV

Classification

Tolerance
±μV

Temperature ℃

S

1064.18

10 334

D

12

±1

C

24

31

±2

±2.6

1554.8

16 239

D

12

±1

C

24

36

±2

±3

R

1064.18

11 364

D

13

±1

C

27

36

±2

±2.6

1554.8

18 219

D

14

±1

C

28

42

±2

±3

B

1064.18

5 434

D

10

±1

C

20

29

38

±2

±3

±4

1554.8

10 735

D

18

±1.5

C

24

36

48

±2

±3

±4

 Note: if requested, to allow the supply of ± 0.5 ℃ high-precision wire