Thermal resistance thermometer material
Thermal resistance thermometer material

(1)  Pt wire

 

Dia mm

resistance ratio W(100℃)

resistance temperature coefficient α

Usage

Standard

Pt1

0.03~1.00

≥1.39254

 

Standard Pt Resistance Thermometer

GB/T5977 -1999

Pt2

0.02~1.00

 

0.003850±0.000004

A-Tolerance Pt RTD thermometer

Pt3

0.02~1.00

 

0.003850±0.000010

B-Tolerance Pt RTD thermometer

Pt4

≥0.30~1.00

 

≥0.003920

Standard Pt resistance thermometer lead, S or R type thermocouple negative etc.

Pt5

≥0.03~1.00

 

≥0.003840

Industrial Pt resistance thermometer lead and others

(2) FPt wire
FPt wire is metal product Pd wire surface covered with Pt coating by a special process, to replace the expensive Pt wire for thermal resistance thermometer as lead. Pt resistance thermometer and the thermal properties are not affected. FPt wire with 12%Pt, can save the consumption of Pt, thus reducing the cost of Pt resistance thermometer. The properties of FPt are as follows:

      Performance
Variety

Dia
mm

Single weight  g/m

Density
g/cm3

δb,Mpa

Bending frequency

Standard

75%cold working

annealed condition

75%cold working

annealed condition

FPt

0.50

2.5

13.00

340

210

10

16

Qn/ycs3-93

0.45

2.0

Pt

0.50

4.21

21.46

250

130

10

16

(3) RhFe alloy wire(Rh-0.5at%Fe)

Diameter

Main performance

Characteristic and usage

Remark

0.03~0.05

W(R4.2/R273.16k)=0.71±0.005
Relative sensitivityβ4.2k=dR/dFR=6.5~7.5×10-2
R273.16k(at 4.2k) secular change 8×10-6~5×
10-5/year

   High sensitivity, good stability, thermal resistance thermometer parts for 2 ~ 20K deep ultralow temperature precision measurement

supply agreement