Location: Home > Products > Temperature Measurement
Special protection tube
MS type high temperature anti-corrosion protection tube

        The common limit temperature of stainless steel protection tube about 900 ℃; the use temperature of the non-metallic type corundum tube and high-aluminum tube is high, thermal shock-resistant is not satisfactory and air-tightness is easy to friable, scope of use are subject to certain restrictions. The developed corrosion-resistant, heat-resistant alloy protection tube series products can be used for special occasions, especially complex chemical production sector, while also for a number of large complete sets of equipment.

● Features
        MS type thermocouple protection tube is a metal ceramic product refractory metal compound molybdenum disilicide matrix, which overcome Al2O3 protection tube disadvantages in thermal shock-resistant, air-tightness and mechanical; has characteristics of high temperature anti-corrosion, anti-oxidation, anti-air erosion, thermal stability and no phase change etc.; suitable for the oxidation, reduction, oxidation-reduction, neutral atmosphere, chemical corrosive gases and molten metal. This product has been widely used for temperature measurement in natural gas, fertilizer, metallurgy, refractory, ceramics, cement, petrochemical, coal chemical, carbon black, machinery and other industries with good effect.

● Heat-resistant and corrosion

Media

Atmosphere

CO2、SO2、NO2、N2、NO

Inert gas and CO

Wet hydrogen

dry hydrogen

NH3
(H2≤8%)

Cu、Al、
Sn、Pb

Ni

Ultimate-use temperature ℃

1600

1600

1500

1450

1350

1400

1000

1500

Medium

Zn

NaCl+BaCl2

NaCl+KCl+FeCl3

NaOH、K2CO3

thermal shock-resistant

Ultimate-use temperature ℃

940

1050

950

Not use

0℃    1500 ℃ repeated cycle of 10 times not crack

● Size specifications and Tolerance

Prdouct code

Specifications and tolerance   mm

MS

Outer diameter

Tolerance

Inner diameter

Tolerance

 Length

Tolerance

16

±1

9

±2

500~1000

±2

18

±1

10

±2

500~1000

±2

20

±1

12

±2

500~1000

±2

22

±1

14

±2

500~900

±2

25

±1

17

±2

500~1000

±2

28

±1

20

±2

500~900

±2

32

±1

22

±2

500~900

±2

Note: 1. the product hard and brittle, the process in transportation, installation and use should be to prevent the impact, touch and vibration;
2. vertical installation, particularly the use temperature>1300℃;
3. the product has a certain conductivity, the working end should be set corundum tube to prevent short circuits when thermocouple assembly.

Standard:Q/YCS73-1998(supply agreement for specifications not mentioned )